BJTNW - 1780 UNITE

Product Identification

Product ID:1780 UNITE
MSDS Date:07/05/1988
FSC:8010
NIIN:00F014089
MSDS Number: BJTNW

Responsible Party
CALGON VESTAL LABORATORIES
5035 MANSHESTER AVENUE
ST. LOUIS, MO 63110

Emergency Phone: (314) 862-2000 & (314) 535-1810

Info Phone: (314) 535-1810

Preparer: R.C. JENTE

Cage: 21667

Contractor
CONVATEC, BRISTOL-MEYERS SQUIBB CO
147 ST. LOUIS, MO 63166-1096 US

Telephone: 314-535-1810 (DAY)

Cage: 21667

Ingredients

DIMETHYLDIALLYLAMMONIUM CHLORIDE, ACRYLAMIDE POLYMER

CAS: 26590-05-6

Fraction By Weight: <10%

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES/SKIN: NOT EXPECTED TO CAUSE
IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES/SKIN: NOT EXPECTED TO CAUSE IRRITATION.

First Aid

First Aid:EYES/SKIN: FLUSH W/PLENTY OF WATER FOR AT LEAST 15MINUTES.
OBTAIN MEDICAL ATTENTION IN ALL CASES IF IRRITATION DEVELOPS./

Fire Fighting

Extinguishing Media:NON-FLAMMABLE
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS.

Accidental Release

Spill Release Procedures:CONTAIN SPILL.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE.
READ & OBSERVE LABEL PRECAUTIONS. STORE IN HEATED BUILDINGS.
Other Precautions:KEEP FROM FREEZING. IF FROZEN/THAW & REMIX BEFORE
USE. UPON FREEZING/STRATIFICATION MAY OCCUR/BUT WILL BECOME
HOMOGENEOUS AGAIN AFTER AGITATION.

Exposure Controls

Respiratory Protection:NOT REQUIRED.
Ventilation:LOCAL EXHAUST: RECOMMENDED.
Work Hygienic Practices:WASH AFTER HANDLING.
Supplemental Safety and Health
PRODUCT PRODUCES A LARGE FLOC FROM PAINT OVERSPRAY THAT HAS BEEN
DETACHEFIED & DISPERSED IN SOLUTION. PRODUCTS WORKS OVER A WIDE PH
RANGE.

Chemical Properties

Boiling Pt:B.P. Text:>212F
Vapor Pres:AS WATER
Vapor Density:AS WATER
Spec Gravity:0.989
pH: 6.75
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR LIQUID W/NO ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS
Stability Condition to Avoid:FREEZING

Disposal

Waste Disposal Methods:FLUSH TO SANITARY SEWER. AVOID DISPOSING OF
MATERIAL TO LAKES, PONDS & STREAMS. UNDILUTED PRODUCT MAY BE TOXIC
TO FISH.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.